Sign In | Join Free | My polstate.com
China Advanced Instruments Co.,Limited logo
Advanced Instruments Co.,Limited
Advanced Instruments Co.,Limited To Be Advanced in Quality and Service!
Verified Supplier

6 Years

Home > Electrical Test Instrument >

Power Transformer Parameters Diagnosis Instrument Transformer Capacity Tester

Advanced Instruments Co.,Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Power Transformer Parameters Diagnosis Instrument Transformer Capacity Tester

  • 1
  • 2
  • 3

Brand Name : AI

Model Number : KFZ

Certification : ISO9001

Place of Origin : China

MOQ : 1 set Transformer Capacity Tester

Price : Negotiable

Payment Terms : Western Union, T/T, L/C

Supply Ability : 100 sets each month

Delivery Time : 15 days

Packaging Details : Transformer Capacity Tester packed in veneer case

Function : Transformer Parameters Testing Transformer Capacity Tester

Test Parameters : Transformer capacity, no-load current, no-load loss, short circuit voltage, short circuit (load) loss

Capacity test range : 30kVA~3150kVA

Size : 400×300×220mm

Weight : 8kg (Excluding accessories)

Power Supply : 220V, 50Hz

Warranty : 1 year

Color : White

Contact Now

Introduction:

  • Transformer Capacity Tester is specializing in basic electricity, power users adverse tax evasion problems and developed a new instrument to increase design.
  • High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load.
  • The Transformer Capacity Tester is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester.
  • The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.

Specifications:

1 Test Parameters

Transformer capacity, no-load current, no-load loss,

short circuit voltage, short circuit (load) loss

2 Working power Input voltage 185Vac~250Vac
Allowable input voltage 85Vac~264Vac
Frequency 50/60Hz
Allowable frequency 45Hz~65Hz
Input power 40VA
Joint Standard AC socket 60320
3 AC voltage Range 10~650V
Resolution 0.001V
Accuracy 0.2%±0.001V
4 AC Current Range 0.5~60A
Resolution 0.001A
Accuracy 0.2%±0.001A
5 Frequency Range 45Hz~65Hz
Resolution 0.001Hz
Accuracy 0.2%±0.001Hz
6 Power Range 0~39kW
Resolution 0.001kW
Accuracy

<±0.5%(CosΦ>0.1)

±1.0%(0.02<CosΦ<0.1)

7 Capacity test range 10kV Dry type transformer 30kVA~3150kVA
10kV Oil immersed transformer 30kVA~3150kVA
35kV Oil immersed transformer 50kVA~31500kVA
20kV Dry type transformer 50kVA~2500kVA
35kV Dry type transformer 50kVA~2000kVA
8 Environment Operating temperature -10℃~+50℃
Storage temperature -25℃~+70℃
Relative humidity 5%~95%
9 Size 400×300×220mm3
10 Weight ≈8kg (Excluding accessories)

Power Transformer Parameters Diagnosis Instrument Transformer Capacity Tester


Product Tags:

Transformer Capacity Tester

      

Transformer Diagnosis Instrument

      

Power Transformer Diagnosis Instrument

      